Fusible Links are temperature-sensitive, one time devices. Engineered as safety links, they open the circuit if the designed limit temperature is reached.
Item Number | Item Description | Primary UO | Order Multiple |
---|---|---|---|
HFL-4257 | In-line, 257 Degrees F, Pack of 4 | PK | 1 |
HFL-4300 | In-line, 300 Degrees F, Pack of 4 | PK | 1 |
HFL-4333 | In-line, 333 Degrees F, Pack of 4 | PK | 1 |
HFL-5257 | Face Plate, 257 Degrees F, Straight, Pack of 2 | PK | 1 |
HFL-5258 | Face Plate, 257 Degrees F, Right Angle, Pack of 2 | PK | 1 |
HFL-5300 | Face Plate, 300 Degrees F, Straight, Pack of 2 | PK | 1 |
HFL-5301 | Face Plate, 300 Degrees F, Right Angle, Pack of 2 | PK | 1 |
HFL-5333 | Face Plate, 333 Degrees F, Straight, Pack of 2 | PK | 1 |
Item Number | Item Description | Primary UO | Order Multiple |
---|---|---|---|
HFL-4257 | In-line, 257 Degrees F, Pack of 4 | PK | 1 |
HFL-4300 | In-line, 300 Degrees F, Pack of 4 | PK | 1 |
HFL-4333 | In-line, 333 Degrees F, Pack of 4 | PK | 1 |
HFL-5257 | Face Plate, 257 Degrees F, Straight, Pack of 2 | PK | 1 |
HFL-5258 | Face Plate, 257 Degrees F, Right Angle, Pack of 2 | PK | 1 |
HFL-5300 | Face Plate, 300 Degrees F, Straight, Pack of 2 | PK | 1 |
HFL-5301 | Face Plate, 300 Degrees F, Right Angle, Pack of 2 | PK | 1 |
HFL-5333 | Face Plate, 333 Degrees F, Straight, Pack of 2 | PK | 1 |
The sequencers are used in electric heat systems to stage blower motors and heating elements. All sequencers are for 24V control.
Item Number | Item Description | Primary UO | Order Multiple |
---|---|---|---|
HDR-101 | Sequencer, 1 Main Circuit, SPST-NO, Delay On 1-24 sec, Delay Off 45-75 sec | EA | 1 |
HDR-102 | Sequencer, 1 Main Circuit, SPST-NO, Delay On 30-75 sec, Delay Off 1-40 sec | EA | 1 |
HDR-201 | Sequencer, 2 Main Circuits, DPST-NO, Delay On 1-24 sec, Delay Off 45-75 sec | EA | 1 |
HDR-202 | Sequencer, 2 Main Circuits, DPST-NO, Delay On 30-70 sec, Delay Off 1-40 sec | EA | 1 |
HDR-211 | Sequencer, 2 Main Staged Circuits, DPST-NO, Delay On 30-110 sec, Delay Off 1-40 sec | EA | 1 |
HDR-212 | Sequencer, 2 Main Staged Circuits, DPST-NO, Delay On 1-25 sec, Delay Off 50-110 sec | EA | 1 |
HDR-221 | Sequencer, 3 Main Staged Circuits, DPST-NO SPST-NO, Delay On 1-25 sec, Delay Off 50-110 sec | EA | 1 |
HDR-222 | Sequencer, 4 Main Staged Circuits, 2 DPST-NO, Delay On 1-40 sec, Delay Off 50-110 sec | EA | 1 |
Item Number | Item Description | Primary UO | Order Multiple |
---|---|---|---|
HDR-101 | Sequencer, 1 Main Circuit, SPST-NO, Delay On 1-24 sec, Delay Off 45-75 sec | EA | 1 |
HDR-102 | Sequencer, 1 Main Circuit, SPST-NO, Delay On 30-75 sec, Delay Off 1-40 sec | EA | 1 |
HDR-201 | Sequencer, 2 Main Circuits, DPST-NO, Delay On 1-24 sec, Delay Off 45-75 sec | EA | 1 |
HDR-202 | Sequencer, 2 Main Circuits, DPST-NO, Delay On 30-70 sec, Delay Off 1-40 sec | EA | 1 |
HDR-211 | Sequencer, 2 Main Staged Circuits, DPST-NO, Delay On 30-110 sec, Delay Off 1-40 sec | EA | 1 |
HDR-212 | Sequencer, 2 Main Staged Circuits, DPST-NO, Delay On 1-25 sec, Delay Off 50-110 sec | EA | 1 |
HDR-221 | Sequencer, 3 Main Staged Circuits, DPST-NO SPST-NO, Delay On 1-25 sec, Delay Off 50-110 sec | EA | 1 |
HDR-222 | Sequencer, 4 Main Staged Circuits, 2 DPST-NO, Delay On 1-40 sec, Delay Off 50-110 sec | EA | 1 |
This bi-metal switch is used as a manual reset. When temperature condition is met, the device opens. The manual reset can only be reset after proper cool-down of the switch. The HMR-130 is a popular fire stat in ducted air distribution systems. Should temperatures in the duct exceed 130 degree F, the switch opens, shutting down the whole system so no fire or smoke can be spread by the fan.
Item Number | Item Description | Primary UO | Order Multiple |
---|---|---|---|
HMR-130 | Bi-metal Manual Reset Fire Stat | EA | 1 |
Item Number | Item Description | Primary UO | Order Multiple |
---|---|---|---|
HMR-130 | Bi-metal Manual Reset Fire Stat | EA | 1 |